Views: 0 Author: Site Editor Publish Time: 2025-04-21 Origin: Site
NASN POWER modular UPS, special used to IDC data center, is a high-end product launched to market adopting “Energy saving, green, environmental protection” concept. It delivers the best combination of rectifier, filter, charger, inverter and intelligent power protection. Applying innovative current sharing rectifier control, master-slave synchronization in sequence control, multi-level decentralized control and 3-level sine wave modulation technology, it features great efficiency, flexibility and reliability, reduces the investment, operation, maintenance cost.
Highly Reliable and Efficient UPS designed with flexible operating modes parallel solutions up to 4800kVA
Application: Date center, Government, Public infrastructures, Army, Aerospace, Communication, Transportation, Broadcast & TV, Finance, Health Care, Education & Research, Enterprise, Automated production line, etc.
Model | UPS-450/75CM | UPS-600/75CM | UPS-900/75CM | UPS-1200/75CM | ||
Capacity (kVA/kW) | 450 kVA/kW | 600 kVA/kW | 900 kVA/kW | 1200 kVA/kW | ||
AC INPUT | ||||||
Wiring | 3Ph+N+PE | |||||
Rated Voltage | 380V/220VAC, 400V/230VAC, 415V/240VAC | |||||
Voltage Range | 132- 276 VAC, (If 132-176VAC, 50% load max.) | |||||
Frequency Range | 40Hz~70Hz | |||||
Power Woke-in | 60sec | |||||
THDI | < 3% | |||||
Power Factor | ≥ 0.99 | |||||
Bypass Voltage Range | ±20% | |||||
Bypass Frequency Range | 50/60±10% | |||||
Bypass synchronization tracking range | 50/60±4% | |||||
AC OUTPUT | ||||||
Wiring | 3Ph+N+PE | |||||
Output Voltage | 380V/220VAC, 400V/230VAC, 415V/240VAC | |||||
Output Frequency | 50/60±0.5HZ | |||||
Frequency Tracking Range | 50/60±10% | |||||
Output Voltage Tolerance | ≤ ±1% | |||||
Voltage Recovering Time | ≤ 20ms | |||||
Transfer From Mains to Battery Supply | 0ms | |||||
Waveform | Pure sine wave | |||||
Distortion(THDV%) | ≤ 2% (Linear load), ≤ 4% (Non-linear load) | |||||
Overload Capability | 10 minutes at 125% | |||||
EFFICIENCY | ||||||
Double conversion Mode | 96.50% | |||||
ECO mode | 99% | |||||
iECO mode | 99.50% | |||||
Lithium-ion Battery | ||||||
Rated Voltage | ±240V DC | |||||
Battery Voltage Range | ±168V DC~±320V DC | |||||
VRLA Battery | ||||||
Rated Voltage | 40 V DC | |||||
Battery Voltage Range | 32V DC~44V DC | |||||
ENVIRONMENT | ||||||
Temperature Range | -5℃ ~40℃ | |||||
Relative Humidity | ≤ 95%, non-condensation | |||||
Acoustics Noise | ≤ 70dB @1 meters | |||||
Altitude | 5000m, derating if 1000m above | |||||
Protection Class | IP20 | |||||
OTHERS | ||||||
Parallel Configuration | Up to 4 units (N+1) | |||||
EPO | Support | |||||
Communication | RS232/RS485, CAN, USB, Dry contact, SD Card as standard. MODBUS, SNMP (optional) | |||||
Safety Compliance | IEC/EN 62040-1, IEC/EN 60950-1 | |||||
EMC Compatibility & Performance | IEC/EN 62040-2, IEC/EN 62040-3 | |||||
PHYSICAL | ||||||
Dimension WxDxH(mm) | 900*1000*2000 | 1200*1000*2000 | 1800*1000*2000 | 2000*1000*2200 | ||
N.W(kg) | 344 | 387 | 618 | 700 |