Telecom DC-AC Inverters 48V DC 19in Rack Mount IKVA/800W inverter model T48/120-1KS is for popular telecom communication application. Standard 19”/23”, 2U Rackmount; Pure Sine Wave Output;Optional SNMP communication Port,T48/120-1KS is China's leading telecom inverter Product. SNMP option allow the user remote communication access to the inverter.

| MODEL | T48/120-1KS | |
| Technical Index(VA) | 1K | |
| DC input | Rated input voltage (Vdc) | 48Vdc | 
| Rated input current (A) | 21 | |
| Allowable range of input DC voltage (Vdc) | Cutoff voltage  40V--60V Startup voltage 45.5V—57V | |
| Backward noise current | ≤10% | |
| AC by-pass input | Allowable by-pass voltage (Vac) | 260V-180V(±10V) | 
| Rated input current (A) | 8.3 | |
| By-pass conversion time (ms) | ≤5ms | |
| AC output | Rated capacity (VA) | 1K | 
| Rated output power (W) | 800 | |
| Inverter output voltage and frequency | 120Vac,60HZ | |
| Inverter output current (A) | 6.7 | |
| Output voltage precision (V) | 120±1.5% | |
| Output frequency precision (Hz) | 60±0.1% | |
| Waveform | Pure sine wave | |
| Total harmonic distortion (THD) | ≤3% (linear load) | |
| Dynamic response time | 5% (load 0←→100%) | |
| Power factor (PF) | 0.8 | |
| Overload capacity | 100%-120% 60s 121%-150% 10s | |
| Inversion efficiency (80% resistive load) | ≥85% | |
| By-pass conversion time (ms) | ≤5ms | |
| Working environment | Dielectric strength (input and output) | 1500Vac, 1 minute | 
| Noise (1m) | ≤40dB | |
| Operating environment temperature | -20℃~+50℃ | |
| Humidity | 0~90%, no moisture condensation | |
| Operating altitude (m) | ≤2000 | |
| Communication | RS232 and RS485, SNMP optional | |
| Indication | LCD display | Input and output voltage, frequency, output current, temperature, percentage, etc. | 
| inverter status | Normal mains, normal inversion, battery under-voltage and output overload | |
| Mechanical size | Standard rack | 347*482*88 | 
| (Depth × Width × Height) (mm) | ||
| Protection function | DC input reverse polarity protection | Available | 
| Normal protections | Input under-voltage and overvoltage, output overload and short circuit protections, etc. | |